To restrict license checkout Site Configuration > Site Settings > Uncheck Enable clients to checkout licenses.
The Checked out License Restrictions in only enabled when the other setting is enabled.
*** We shall not be liable for any loss or damage of whatever nature (direct, indirect, consequential, or other) whether arising in contract, tort or otherwise, which may arise as a result of your use of (or inability to use) this website, or from your use of (or failure to use) the information on this site.*** 3ds max AutoCAD & Computer repairs and programs I find useful and or free.
Wednesday, September 28, 2016
Tuesday, September 27, 2016
Friday, September 23, 2016
Word Outlook spell checker not working or working intermittently.
Word Outlook spell checker not working or working intermittently. Works on some documents and emails but not others.
1. CTRL+A Select the entire document.
2. In Word and Outlook : Review tab > Language > Set
Proofing Language.
Proofing Language.
3 Uncheck “Do not check spelling or grammar check box”
Wednesday, September 21, 2016
ProSteel to SolidWorks Conversion
1.0 OPEN PROSTEEL
1.1 Open file and saveas a new name. This procedure will convert the object in the file to NON Bentley objects depending on settings.
1.2 Prostructures Tab > 2D > Create ACSI file
Select objects
Command: _PS_CREATE_ACIS Solid kernel objects will be created and the original
Objects are hidden. You may display them with PS_REGEN!
Select all objects to derive Acis objects from:
Select objects: Specify opposite corner: 531 found, 216 groups
Select objects:
Do you want to generate one body per group? No,y
Shall the part resolution remain? Otherwise the highest resolution will be
used. No,y
Do you want to delete the original parts from the converted solid kernel parts?
If not, they will be just hidden. Non
Do you want to have the solid kernel parts on the same layer as the original
parts? No,y
2.0 OPEN ACSI DWG IN SOLIDWORKS
2.1 Import as new part.
2.2 3d curves or Model
1.1 Open file and saveas a new name. This procedure will convert the object in the file to NON Bentley objects depending on settings.
1.2 Prostructures Tab > 2D > Create ACSI file
Select objects
Command: _PS_CREATE_ACIS Solid kernel objects will be created and the original
Objects are hidden. You may display them with PS_REGEN!
Select all objects to derive Acis objects from:
Select objects: Specify opposite corner: 531 found, 216 groups
Select objects:
Do you want to generate one body per group? No,
Shall the part resolution remain? Otherwise the highest resolution will be
used. No,
Do you want to delete the original parts from the converted solid kernel parts?
If not, they will be just hidden. No
Do you want to have the solid kernel parts on the same layer as the original
parts? No,
2.0 OPEN ACSI DWG IN SOLIDWORKS
2.1 Import as new part.
2.2 3d curves or Model
ProSteel to SolidWorks Conversion
1.0 OPEN PROSTEEL
1.1 Open file and saveas a new name. This procedure will convert the object in the file to NON Bentley objects depending on settings.
1.2 Prostructures Tab > 2D > Create ACSI file
Select objects
Command: _PS_CREATE_ACIS Solid kernel objects will be created and the original
Objects are hidden. You may display them with PS_REGEN!
Select all objects to derive Acis objects from:
Select objects: Specify opposite corner: 531 found, 216 groups
Select objects:
Do you want to generate one body per group? No,y
Shall the part resolution remain? Otherwise the highest resolution will be
used. No,y
Do you want to delete the original parts from the converted solid kernel parts?
If not, they will be just hidden. Non
Do you want to have the solid kernel parts on the same layer as the original
parts? No,y
2.0 OPEN ACSI DWG IN SOLIDWORKS
2.1 Import as new part.
2.2 3d curves or Model
1.1 Open file and saveas a new name. This procedure will convert the object in the file to NON Bentley objects depending on settings.
1.2 Prostructures Tab > 2D > Create ACSI file
Select objects
Command: _PS_CREATE_ACIS Solid kernel objects will be created and the original
Objects are hidden. You may display them with PS_REGEN!
Select all objects to derive Acis objects from:
Select objects: Specify opposite corner: 531 found, 216 groups
Select objects:
Do you want to generate one body per group? No,
Shall the part resolution remain? Otherwise the highest resolution will be
used. No,
Do you want to delete the original parts from the converted solid kernel parts?
If not, they will be just hidden. No
Do you want to have the solid kernel parts on the same layer as the original
parts? No,
2.0 OPEN ACSI DWG IN SOLIDWORKS
2.1 Import as new part.
2.2 3d curves or Model
Navisworks Objects not Shading Correctly
To start Options click on the Program Icon
in upper left hand corner. 

Set “DWG Loader Version” to “2014”, the
AutoCAD version you have the Object Enablers (OE) installed on.
Set DWG\DXF
Render Type to “Shaded” Can cause pipes to show wireframe and bends to shade.
If objects are not showing make sure you have the Object enablers installed on AutoCAD.
Subscribe to:
Posts (Atom)
Popular Posts
-
FXSAPIDebugLogFile.txt is related to the Windows Fax and Scan service. To disable this service: Control Panel > Programs and Feat...
-
AutoCAD Fatal ERROR: Unhandled access violation reading 0X0018 Exception at e0511224h Recover or Audit and purge file. REPAIR AutoCAD fro...
-
In AutoCAD 12 and higher type "Import" and select STEP file format- select file and open OR download Sycode http://www.sycode....
-
Extract text from Autocad and create an Excel file. command: EATTEXT Start up the EATTEXT command and you w...
-
http://www.symantec.com/connect/articles/understanding-error-1603-fatal-error-during-installation This error message is displayed by the M...
-
DispSilh 0 PLANTINSULATIONDISPLAY <ON>: ON in Plant 3d NavisWorks In the Standard properties Turn OFF insulation “Iso Inf...
-
Licensing: The security system (Softlock license manager) is not functioning or is improperly installed 1. Msconfig uncheck any FLEXnet p...
-
1.0 Attach reference files and Merge (xref & bind ) Microstation 1.1 File >References Tools > Attach ...
-
WSCOMMCNTR4.EXE INFOCENTER TURN OFF Windows 7 AutoCAD 2014. Other versions will have a similar key. - Need to edit the registry. Good pra...
-
DRAG AND DROPS DragHeight and DragWidth HKEY_CURRENT_USER\Control Panel\Desktop In the right side pane, look for the following Values....