http://forums.autodesk.com/t5/navisworks-forum/rcs-file-appears-in-nwf-but-does-not-appear-in-nwd/td-p/5868049
If you want to “Save” point clouds in NWD files, Users need access to the point cloud location.
If you want to send the NWD out to clients the .nwf must be Published rather than saved. In the Publish dialog box check "Embed ReCap and Texture data". Expect a fairly large .nwd file as a result.
*** We shall not be liable for any loss or damage of whatever nature (direct, indirect, consequential, or other) whether arising in contract, tort or otherwise, which may arise as a result of your use of (or inability to use) this website, or from your use of (or failure to use) the information on this site.*** 3ds max AutoCAD & Computer repairs and programs I find useful and or free.
Wednesday, October 5, 2016
Monday, October 3, 2016
Bentely Navigator Microstation Rotate View is in 3point
When rotating view I have to pick on the x and y direction instead of the dynamic rotation.
Select rotate on the left you will see a "Rotate View" tab. Select the tab and change the Method to Dynamic.
Select rotate on the left you will see a "Rotate View" tab. Select the tab and change the Method to Dynamic.
Wednesday, September 28, 2016
Bentley Select server license checkout restrictions
To restrict license checkout Site Configuration > Site Settings > Uncheck Enable clients to checkout licenses.
The Checked out License Restrictions in only enabled when the other setting is enabled.
The Checked out License Restrictions in only enabled when the other setting is enabled.
Tuesday, September 27, 2016
Friday, September 23, 2016
Word Outlook spell checker not working or working intermittently.
Word Outlook spell checker not working or working intermittently. Works on some documents and emails but not others.
1. CTRL+A Select the entire document.
2. In Word and Outlook : Review tab > Language > Set
Proofing Language.
Proofing Language.
3 Uncheck “Do not check spelling or grammar check box”
Wednesday, September 21, 2016
ProSteel to SolidWorks Conversion
1.0 OPEN PROSTEEL
1.1 Open file and saveas a new name. This procedure will convert the object in the file to NON Bentley objects depending on settings.
1.2 Prostructures Tab > 2D > Create ACSI file
Select objects
Command: _PS_CREATE_ACIS Solid kernel objects will be created and the original
Objects are hidden. You may display them with PS_REGEN!
Select all objects to derive Acis objects from:
Select objects: Specify opposite corner: 531 found, 216 groups
Select objects:
Do you want to generate one body per group? No,y
Shall the part resolution remain? Otherwise the highest resolution will be
used. No,y
Do you want to delete the original parts from the converted solid kernel parts?
If not, they will be just hidden. Non
Do you want to have the solid kernel parts on the same layer as the original
parts? No,y
2.0 OPEN ACSI DWG IN SOLIDWORKS
2.1 Import as new part.
2.2 3d curves or Model
1.1 Open file and saveas a new name. This procedure will convert the object in the file to NON Bentley objects depending on settings.
1.2 Prostructures Tab > 2D > Create ACSI file
Select objects
Command: _PS_CREATE_ACIS Solid kernel objects will be created and the original
Objects are hidden. You may display them with PS_REGEN!
Select all objects to derive Acis objects from:
Select objects: Specify opposite corner: 531 found, 216 groups
Select objects:
Do you want to generate one body per group? No,
Shall the part resolution remain? Otherwise the highest resolution will be
used. No,
Do you want to delete the original parts from the converted solid kernel parts?
If not, they will be just hidden. No
Do you want to have the solid kernel parts on the same layer as the original
parts? No,
2.0 OPEN ACSI DWG IN SOLIDWORKS
2.1 Import as new part.
2.2 3d curves or Model
ProSteel to SolidWorks Conversion
1.0 OPEN PROSTEEL
1.1 Open file and saveas a new name. This procedure will convert the object in the file to NON Bentley objects depending on settings.
1.2 Prostructures Tab > 2D > Create ACSI file
Select objects
Command: _PS_CREATE_ACIS Solid kernel objects will be created and the original
Objects are hidden. You may display them with PS_REGEN!
Select all objects to derive Acis objects from:
Select objects: Specify opposite corner: 531 found, 216 groups
Select objects:
Do you want to generate one body per group? No,y
Shall the part resolution remain? Otherwise the highest resolution will be
used. No,y
Do you want to delete the original parts from the converted solid kernel parts?
If not, they will be just hidden. Non
Do you want to have the solid kernel parts on the same layer as the original
parts? No,y
2.0 OPEN ACSI DWG IN SOLIDWORKS
2.1 Import as new part.
2.2 3d curves or Model
1.1 Open file and saveas a new name. This procedure will convert the object in the file to NON Bentley objects depending on settings.
1.2 Prostructures Tab > 2D > Create ACSI file
Select objects
Command: _PS_CREATE_ACIS Solid kernel objects will be created and the original
Objects are hidden. You may display them with PS_REGEN!
Select all objects to derive Acis objects from:
Select objects: Specify opposite corner: 531 found, 216 groups
Select objects:
Do you want to generate one body per group? No,
Shall the part resolution remain? Otherwise the highest resolution will be
used. No,
Do you want to delete the original parts from the converted solid kernel parts?
If not, they will be just hidden. No
Do you want to have the solid kernel parts on the same layer as the original
parts? No,
2.0 OPEN ACSI DWG IN SOLIDWORKS
2.1 Import as new part.
2.2 3d curves or Model
Navisworks Objects not Shading Correctly
To start Options click on the Program Icon
in upper left hand corner.
Set “DWG Loader Version” to “2014”, the
AutoCAD version you have the Object Enablers (OE) installed on.
Set DWG\DXF
Render Type to “Shaded” Can cause pipes to show wireframe and bends to shade.
If objects are not showing make sure you have the Object enablers installed on AutoCAD.
Wednesday, August 31, 2016
Autocad inserted images disappear
Try reducing the max resolution to 2500 pixels. Open the file in paint and select resize > pixels and input a 2500 for the highest number of width or height.
PDF coments will not print or I don't want the comments to print
File > Print > select documents and Markups in the Comments & Forms dropdown box. If you do not want the comments to print select Document.
Thursday, July 28, 2016
Bentley STAIRS AND OTHER OBJECTS NOT SHADING
STAIRS AND OTHER OBJECTS NOT SHADING
Install 32 bit civil Object enablers on Bentley RealDWG- Civil3D_2014_OE_32Bit_SP2.exe
Other options:
1.1 Create another Navigator icon on the desktop. Right click on it and choose properties. Add -restoredefaults to the end of the target path.
1.2 Uninstall \ Install on Bentley Navigator latest version and RealDwg
2.0 INSTALL OBJECT ENABLER FOR REALDWG
2.1 Uninstall Reinstall ProSteel OE
2.2 Civil3D_2014_OE_32Bit_SP2.exe
2.3 Install realdwg version
3.0 SETTINGS
3.1 Update video card drivers
3.2 Purge and audit dwg files.
3.3 Crashes - when changing focus & rotating
3.3.1 Settings > Configuration > New > Variable = QV_D3DVERSION
New Value = 9 or 0 , see which one works.
3.4 Show most items shaded. Some items do not show up.
3.4.1 Open View > Options > From AutoCAD Registry, Active View Direction and Hidden or Shaded
3.5 If still crashing turn off\on hardware acceleration, and or update video card drivers.
Install 32 bit civil Object enablers on Bentley RealDWG- Civil3D_2014_OE_32Bit_SP2.exe
Other options:
1.1 Create another Navigator icon on the desktop. Right click on it and choose properties. Add -restoredefaults to the end of the target path.
1.2 Uninstall \ Install on Bentley Navigator latest version and RealDwg
2.0 INSTALL OBJECT ENABLER FOR REALDWG
2.1 Uninstall Reinstall ProSteel OE
2.2 Civil3D_2014_OE_32Bit_SP2.exe
2.3 Install realdwg version
3.0 SETTINGS
3.1 Update video card drivers
3.2 Purge and audit dwg files.
3.3 Crashes - when changing focus & rotating
3.3.1 Settings > Configuration > New > Variable = QV_D3DVERSION
New Value = 9 or 0 , see which one works.
3.4 Show most items shaded. Some items do not show up.
3.4.1 Open View > Options > From AutoCAD Registry, Active View Direction and Hidden or Shaded
3.5 If still crashing turn off\on hardware acceleration, and or update video card drivers.
Tuesday, July 26, 2016
Bentley AutoPipe Cant open file
E512-65: The model cannot be opened for editing.
Click “Ok” another dialog box opens which asks
“Would you like to save to another directory”. Then save file to new location and move it back to where you want it.
“Would you like to save to another directory”. Then save file to new location and move it back to where you want it.
Thursday, June 30, 2016
AutoPLANT file loads and then hangs up
Symptoms:
The file starts to load and then stalls, freezes, stops loading using the access databases.
Solution:
Check if the MDB files are missing. Reimport the files.
Purge and audit drawing
Open Document Manager, open project, Check location path
then delete file from project.
Close Document Manager.
Open the Relationship Manager (the project should not be
opened with Document Manager)
Select Tools, Document Tools, Add to Project and select the
file on your desktop
Expand the plus sign, and check both boxes
Then on the first line select the Target location
Click Add
Open Document Manager and verify that all is correct and the
drawings opens.
The file starts to load and then stalls, freezes, stops loading using the access databases.
Solution:
Check if the MDB files are missing. Reimport the files.
Purge and audit drawing
Open Document Manager, open project, Check location path
then delete file from project.
Close Document Manager.
Open the Relationship Manager (the project should not be
opened with Document Manager)
Select Tools, Document Tools, Add to Project and select the
file on your desktop
Expand the plus sign, and check both boxes
Then on the first line select the Target location
Click Add
Open Document Manager and verify that all is correct and the
drawings opens.
Friday, May 27, 2016
Bentley ATDB0801 Unable to update drawing name in drawing' s area.
one or more objects in drawing cannot be saved to the specified format
Purge > clean database > view dataBASE
Purge > clean database > view dataBASE
Wednesday, May 11, 2016
Plotting dwgtopdf PDF Not showing up issues
Plotting dwg to pdf issues
1. In your plot dialog select the DWG to PDF > Properties > Custom Properties > Custom Properties (down below the other custom properties) > Raster Image Resolution DPI or Black and White and set it to a lower number. This may make your images look worse so go as high as you can.
2. Check the pixel count of the image, make it smaller ~2500 pixels.
3. RASTERPERCENT = 90 Sets the maximum percentage of available virtual memory that is allowed for plotting a raster image. & RASTERTHRESHOLD =100 If the plotted raster image exceeds this threshold, the availability of system memory is checked. The plot is aborted if the image is too big for the available memory.
4. Copy pictures into same folder as DWG.
1. In your plot dialog select the DWG to PDF > Properties > Custom Properties > Custom Properties (down below the other custom properties) > Raster Image Resolution DPI or Black and White and set it to a lower number. This may make your images look worse so go as high as you can.
2. Check the pixel count of the image, make it smaller ~2500 pixels.
3. RASTERPERCENT = 90 Sets the maximum percentage of available virtual memory that is allowed for plotting a raster image. & RASTERTHRESHOLD =100 If the plotted raster image exceeds this threshold, the availability of system memory is checked. The plot is aborted if the image is too big for the available memory.
4. Copy pictures into same folder as DWG.
Thursday, May 5, 2016
Simulation mechanical locked to a machine AutoCAD Licensing issues
As Always backup prior to deleting. These are suggestions, I assume no responsibility for these ideas.
It may be necessary to delete the following folders:
C:\ProgramData\Autodesk\ADUT
C:\Users\{username}\AppData\Roaming\Autodesk\ADUT
And delete the files that begin with adskflex… that are in the FLEXnet folder:
C:\ProgramData\FLEXnet\
It may be necessary to delete the following folders:
C:\ProgramData\Autodesk\ADUT
C:\Users\{username}\AppData\Roaming\Autodesk\ADUT
And delete the files that begin with adskflex… that are in the FLEXnet folder:
C:\ProgramData\FLEXnet\
Wednesday, May 4, 2016
ACInetEngine19.dll AutoCAD Could not write to the Internet cache on your computer
AcInetEngine19 Could not write to the Internet cache on your computer.
Turn off InfoCenter in registry. Then try AutoCAD.
Uninstall AutoCAD 360. Then try AutoCAD again.
-
How to Turn Off InfoCenter. Regedit and set to 0
[HKEY_CURRENT_USER\Software\Autodesk\AutoCAD\R19.1\ACAD-D001:409\InfoCenter]
InfoCenterOn"=dword:00000000
-
How to Uninstall AutoCAD 360.
Control panel
Uninstall programs
AutoCAD
Uninstall/Change
Add and Remove Features
Uncheck Autodesk 360
Turn off InfoCenter in registry. Then try AutoCAD.
Uninstall AutoCAD 360. Then try AutoCAD again.
-
How to Turn Off InfoCenter. Regedit and set to 0
[HKEY_CURRENT_USER\Software\Autodesk\AutoCAD\R19.1\ACAD-D001:409\InfoCenter]
InfoCenterOn"=dword:00000000
-
How to Uninstall AutoCAD 360.
Control panel
Uninstall programs
AutoCAD
Uninstall/Change
Add and Remove Features
Uncheck Autodesk 360
Tuesday, May 3, 2016
Bentley Dialog box not working Remove KB3139940
Removed KB3139940
Start > Control Panel > Programs and features > view installed updates. Search for KBKB3139940. If you have a network administrator have them remove this from the install list. If not you may have to uninstall this after windows updated
Start > Control Panel > Programs and features > view installed updates. Search for KBKB3139940. If you have a network administrator have them remove this from the install list. If not you may have to uninstall this after windows updated
Thursday, April 21, 2016
Best AutoCAD viewers
Dassault “DraftSight” Fully functional cad package! For Free!
https://www.3ds.com/products-services/draftsight-cad-software/free-download/
Bentley “View” you can print 3D PDF files! View Bentley objects.
https://www.bentley.com/en/products/product-line/modeling-and-visualization-software/bentley-view
AutoDesk “TrueView” standard viewer for AutoCAD.
http://www.autodesk.com/products/dwg/viewers
Dassault eDrawings
http://www.edrawingsviewer.com/
https://www.3ds.com/products-services/draftsight-cad-software/free-download/
Bentley “View” you can print 3D PDF files! View Bentley objects.
https://www.bentley.com/en/products/product-line/modeling-and-visualization-software/bentley-view
AutoDesk “TrueView” standard viewer for AutoCAD.
http://www.autodesk.com/products/dwg/viewers
Dassault eDrawings
http://www.edrawingsviewer.com/
Wednesday, March 23, 2016
Mapped drive to UNC Windows Explorer address bar
Copy UNC network path (not drive letter) for paths on mapped drives from Windows Explorer
1. In Windows Explorer, hold the shift button down, r-click on the file, and select "Copy as path".
2. Insert a Hyperlink in the email and paste in the address field of the Hyperlink dialogue box. (Shortcut: ctrl-K ctrl-V + OK). At this point, the link will display the mapped drive letter as the root (G:\test.xml). Select OK.
3. Now, r-click on link on link and select "Edit Hyperlink..." you will notice that the Address field has been translated back into the full UNC path (\\mapped\test.xml).
4. With your mouse in the Address field, hit ctrl-A and ctrl-C to copy the full path to your clipboard, then move your cursor to the top field ("Text to Display:") hit ctrl-A and ctrl-V to display it correctly in your email.
1. In Windows Explorer, hold the shift button down, r-click on the file, and select "Copy as path".
2. Insert a Hyperlink in the email and paste in the address field of the Hyperlink dialogue box. (Shortcut: ctrl-K ctrl-V + OK). At this point, the link will display the mapped drive letter as the root (G:\test.xml). Select OK.
3. Now, r-click on link on link and select "Edit Hyperlink..." you will notice that the Address field has been translated back into the full UNC path (\\mapped\test.xml).
4. With your mouse in the Address field, hit ctrl-A and ctrl-C to copy the full path to your clipboard, then move your cursor to the top field ("Text to Display:") hit ctrl-A and ctrl-V to display it correctly in your email.
Thursday, March 17, 2016
WSCOMMCNTR4.EXE using resources INFOCENTER TURN OFF
WSCOMMCNTR4.EXE INFOCENTER TURN OFF Windows 7 AutoCAD 2014. Other versions will have a similar key.
-
Need to edit the registry. Good practice to create a restore point first.
-
Regedit
HKEY_CURRENT_USER\Software\Autodesk\AutoCAD\R19.1\ACAD-D001:409\InfoCenter
InfoCenterOn =0
resources
In my opinion you can turn this off and sleep well at night.
InfoCenter is a feature used in several Autodesk products. It consists of a set of tools on the right side of the title bar that enable you to access product-related information sources. Depending on the Autodesk product and the configuration, these tools might differ.
-
Need to edit the registry. Good practice to create a restore point first.
-
Regedit
HKEY_CURRENT_USER\Software\Autodesk\AutoCAD\R19.1\ACAD-D001:409\InfoCenter
InfoCenterOn =0
resources
In my opinion you can turn this off and sleep well at night.
InfoCenter is a feature used in several Autodesk products. It consists of a set of tools on the right side of the title bar that enable you to access product-related information sources. Depending on the Autodesk product and the configuration, these tools might differ.
Tuesday, March 15, 2016
Bentley AutoPLANT SELECTION DIALOG was cancelled message when trying to update components PCF EXPORT broke
The workaround for this issue is to uninstall windows update KB3139940
Bentley some functions stopped working after windows updates.
Selection dialog was cancelled message when trying to update components
PCF export does not work.
Start > Control Panel > Programs and Features > View installed updates > Look for Microsoft Windows and remove KB3139940
If you have a network administrator you will need to keep this from being reinstalled.
Bentley some functions stopped working after windows updates.
Selection dialog was cancelled message when trying to update components
PCF export does not work.
Start > Control Panel > Programs and Features > View installed updates > Look for Microsoft Windows and remove KB3139940
If you have a network administrator you will need to keep this from being reinstalled.
Wednesday, March 9, 2016
AutoCAD Purges Slow dimension or text picking
AutoCAD 2014 Purges
1. Slow dimension or text picking use DGNPURGE then AutoCAD purge
https://knowledge.autodesk.com/support/autocad/downloads/caas/downloads/content/autocad-C2-AE-dgn-hotfix.html
2. Radical Purge (RPurge)
https://apps.autodesk.com/Detail/Index?id=appstore.exchange.autodesk.com%3Aradicalpurge_windows32and64%3Aen
3. DWG-Purge
https://apps.autodesk.com/ACD/en/Detail/HelpDoc?id=appstore.exchange.autodesk.com%3Adrawingpurge_windows32and64%3Aen
1. Slow dimension or text picking use DGNPURGE then AutoCAD purge
https://knowledge.autodesk.com/support/autocad/downloads/caas/downloads/content/autocad-C2-AE-dgn-hotfix.html
2. Radical Purge (RPurge)
https://apps.autodesk.com/Detail/Index?id=appstore.exchange.autodesk.com%3Aradicalpurge_windows32and64%3Aen
3. DWG-Purge
https://apps.autodesk.com/ACD/en/Detail/HelpDoc?id=appstore.exchange.autodesk.com%3Adrawingpurge_windows32and64%3Aen
Friday, March 4, 2016
Bentley Prosteel ProStructures Import .PXF .STP .SDF .PRO .PSB .STD .STP .XML
In Bentley ProSteel Type PS_IMPORT
Select file .PXF .STP .SDF .PRO .PSB .STD .STP .XML
.PXF - Bentley PXF
.STP - DSTV-Production interface
.SDF - SDNF
.PRO - SCIA Esa PT
.PSB - ProSteel exchange data
.STD - STAAD III
.STP - CIMSteeL/2
.XML - RAM
AutoCAD Type Import
.3ds .sat .model .sessions .exp .exp .dlv3 .CATPart .CATProduct .fbx .igs .iges .jt .wmf .dgn .prt .x_b .x_t ‘prt .g .neu .3dm .prs .sldprt .asm .sldasm . .ste .ste .step
Select file .PXF .STP .SDF .PRO .PSB .STD .STP .XML
.PXF - Bentley PXF
.STP - DSTV-Production interface
.SDF - SDNF
.PRO - SCIA Esa PT
.PSB - ProSteel exchange data
.STD - STAAD III
.STP - CIMSteeL/2
.XML - RAM
AutoCAD Type Import
.3ds .sat .model .sessions .exp .exp .dlv3 .CATPart .CATProduct .fbx .igs .iges .jt .wmf .dgn .prt .x_b .x_t ‘prt .g .neu .3dm .prs .sldprt .asm .sldasm . .ste .ste .step
Thursday, February 25, 2016
Slow ViewPoint, Slow Text and Dimension changes in AutoCAD
Slow ViewPoint, Text
and Dimension changes in AutoCAD
1. Set DISPSILH = 0 (we set this to 1 for plotting so extra lines do not show up in solids)
2. Work in 2d WireFrame display style
3. Audit and repair and purge all xrefs.
4. View cube is slow, Use VP (DDVPOINT) or right click in the toolbar area and open and use the “View” toolbar.
5. If you insist on using the Viewcube uncheck “Use view transitions when switching views” Options > 3d Modeleing > ViewCube.
6. BREP removes solids history (subtracted joined ext. can lower file size and speed up display of solids)
8. Change the desktop theme in Windows to Windows Basic.
9. Options > System tab > Layout Regen Options, Start with Regen when switching layouts.
10. Turn on hardware Acceleration.
11. Other purge options available at AutoDESK.
DGNPURGE - K:\ACAD\_Patches\_AutoCAD Patches\2014\DGN PURGE
DWG-PURGE - K:\ACAD\_Patches\_AutoCAD Patches\2014\Drawing-Purge
RPURGE - K:\ACAD\_Patches\_AutoCAD Patches\2014\RADICAL PURGE
BREP - Autocad solid command that removes history
DISPSILH (System Variable) Controls display of silhouette edges of 3D solid and surface objects in the Wireframe or 2D Wireframe visual styles.
DIMENSIONS AND TEXT
1. Slow dimension or text picking use DGNPURGE then AutoCAD purge
https://knowledge.autodesk.com/support/autocad/downloads/caas/downloads/content/autocad-C2-AE-dgn-hotfix.html
2. Radical Purge
https://apps.autodesk.com/Detail/Index?id=appstore.exchange.autodesk.com%3Aradicalpurge_windows32and64%3Aen
3. DWG-Purge
https://apps.autodesk.com/ACD/en/Detail/HelpDoc?id=appstore.exchange.autodesk.com%3Adrawingpurge_windows32and64%3Aen
Tuesday, February 23, 2016
Bentley At.ini alert Unable to read AT.INI AutoPLANT
THIS IS A VERY DANGEROUS PROCEDURE I HAVE DONE MANY TIMES. I ASSUME NO RESPOSIBILITY FOR THIS PROCEDURE OR YOUR STUPIDITY...
Uninstall ALL Bentley, See below "Full Bentley Uninstall", remove following keys and reinstall AutoPLANT.
HKEY_LOCAL_MACHINE\Software\Wow6432Node\Bentley\ (delete key)
[HKEY_CLASSES_ROOT\CLSID\{720080E7-D479-4053-94B3-112B9809698B}\InprocServer32\
(8.11.11.1, is SS6)
**Complete uninstall of Bentley**
Control panel sort be publisher and remove all Bentley
☐ Control panel sort be publisher and remove all Bentley
☐ HKEY_Current_User\SOFTWARE\BENTLEY\
☐ HKEY_Local_Machine\SOFTWARE\BENTLEY\
*Delete Bentley from following*
Go to Start, Programs, Right click, Delete Bentley
Delete Desktop Icons - Related Files
C:\BentleyDownloads – All files
C:\Program Files\Bentley - Delete Folders
C:\Program Files\Common Files\Bentley
C:\Program Files (x86)\Bentley and
C:\Program Files (x86)\ Common Files\Bentley
C:\ProgramData\Bentley
C:\Users\Each User\AppData\Local\Bentley
C:\Users\Each User\AppData\Roaming\ Bentley
C:\Users\Documents Related Files
C:\Users\Public\Documents - Related Files
C:\Users\Each User\Documents - Related Files
Delete %temp% files = C:\Users\UseName\AppData\Local\Temp – All files
Delete any other references to Bentley
Go to Start, Programs, Right click, Delete Bentley
Delete Desktop Icons - Related Files
Run CCleaner
Reinstall AutoPLANT
Uninstall ALL Bentley, See below "Full Bentley Uninstall", remove following keys and reinstall AutoPLANT.
HKEY_LOCAL_MACHINE\Software\Wow6432Node\Bentley\ (delete key)
[HKEY_CLASSES_ROOT\CLSID\{720080E7-D479-4053-94B3-112B9809698B}\InprocServer32\
(8.11.11.1, is SS6)
**Complete uninstall of Bentley**
Control panel sort be publisher and remove all Bentley
☐ Control panel sort be publisher and remove all Bentley
☐ HKEY_Current_User\SOFTWARE\BENTLEY\
☐ HKEY_Local_Machine\SOFTWARE\BENTLEY\
*Delete Bentley from following*
Go to Start, Programs, Right click, Delete Bentley
Delete Desktop Icons - Related Files
C:\BentleyDownloads – All files
C:\Program Files\Bentley - Delete Folders
C:\Program Files\Common Files\Bentley
C:\Program Files (x86)\Bentley and
C:\Program Files (x86)\ Common Files\Bentley
C:\ProgramData\Bentley
C:\Users\Each User\AppData\Local\Bentley
C:\Users\Each User\AppData\Roaming\ Bentley
C:\Users\Documents Related Files
C:\Users\Public\Documents - Related Files
C:\Users\Each User\Documents - Related Files
Delete %temp% files = C:\Users\UseName\AppData\Local\Temp – All files
Delete any other references to Bentley
Go to Start, Programs, Right click, Delete Bentley
Delete Desktop Icons - Related Files
Run CCleaner
Reinstall AutoPLANT
Friday, February 19, 2016
AutoCAD resize Plot Preview area
Plot extents or window the area you want to plot.
Select apply to layout
Cancel
Also
Options > Display > Display paper background
Select apply to layout
Cancel
Also
Options > Display > Display paper background
Wednesday, February 17, 2016
AutoCAD - ACADINFO see all variable settings
ACADINFO is a utility for gathering information about
your AutoCAD installation and current setup, Variable settings file locations. The routine will examine your system and write a text file.
your AutoCAD installation and current setup, Variable settings file locations. The routine will examine your system and write a text file.
Thursday, February 11, 2016
Excel Files Load\start automatically on startup
Move\Delete files in this folder
C:\Users\UserName\AppData\Roaming\Microsoft\Excel\XLSTART
C:\Users\UserName\AppData\Roaming\Microsoft\Excel\XLSTART
Monday, February 8, 2016
FIELDDISPLAY -Turn off/on the grey background of a Attribute or field Text
Turn off/on the grey background of a Attribute. The grey background mask doesn't print.
FIELDDISPLAY system variable.
FIELDDISPLAY: <0> Turn off grey background mask.
<1> Turn on grey background mask.
1>0>
<0><1>
1>0> <0><1>
1>0> The background of your text is shaded and you want to remove the shading in AutoCAD.
Type FieldDisplay and set it to 0
<0><1>1>0>
FIELDDISPLAY -Turn off/on the grey background of a Attribute or field Text
FIELDDISPLAY system variable.
FIELDDISPLAY: <0> Turn off grey background mask.
<1> Turn on grey background mask.
1>0>
<0><1>
1>0> <0><1>
1>0> The background of your text is shaded and you want to remove the shading in AutoCAD.
Type FieldDisplay and set it to 0
<0><1>1>0>
FIELDDISPLAY -Turn off/on the grey background of a Attribute or field Text
Friday, February 5, 2016
The current Drawing is already registered in the document registry with document ID
http://communities.bentley.com/products/plant/design___engineering/w/plant_design_and_engineering__wiki/error-document-is-already-registered-in-document-register-with-document-id-xxxxxxxxx-tn
The AutoPLANT error "The current Drawing XXXXXX is already registered in the document registry with document ID XXXXX" (seen Below) occurs when the drawing's name and Doc ID differ from drawing name and Doc ID in the database. The error can be easily corrected.
To resolve this error please use the following steps:
1.Move the drawing to a different location. Tip: The local desktop is suitable and convenient location
2.Open AutoCAD
3.Turn on Drawing Access Mode by going to AutoPLANT 3D>Drawing Access Mode. Activating Drawing Access Mode will open the project selection prompt every time AutoPLANT is started
4.Open the drawing from AutoCAD
5.Start AutoPLANT
6.When prompted for a project: chose Configuration. Then choose the Project which has the same units as the drawing.
7.Once open, save the drawing then close.
8.Open Relation Ship Manager
9.Delete instances of the drawing out of the project to remove drawing data from the project database. Moving the drawing to a different location in step 1 will prevent it from being deleted in this step. When deleting the drawings: ensure that the drawings deleted are duplications not a different drawing with the same name.
10.Start AutoCAD
11.Open the drawing
12.Start AutoPLANT
13.When prompted choose project then choose the original project
14.Once open save the drawing and close
15.Use Relation Ship Manager to move the drawing from your desktop to the previous location
The drawing is now is in the project with a new DOC_ID and it should not display the error when opening.
The AutoPLANT error "The current Drawing XXXXXX is already registered in the document registry with document ID XXXXX" (seen Below) occurs when the drawing's name and Doc ID differ from drawing name and Doc ID in the database. The error can be easily corrected.
To resolve this error please use the following steps:
1.Move the drawing to a different location. Tip: The local desktop is suitable and convenient location
2.Open AutoCAD
3.Turn on Drawing Access Mode by going to AutoPLANT 3D>Drawing Access Mode. Activating Drawing Access Mode will open the project selection prompt every time AutoPLANT is started
4.Open the drawing from AutoCAD
5.Start AutoPLANT
6.When prompted for a project: chose Configuration. Then choose the Project which has the same units as the drawing.
7.Once open, save the drawing then close.
8.Open Relation Ship Manager
9.Delete instances of the drawing out of the project to remove drawing data from the project database. Moving the drawing to a different location in step 1 will prevent it from being deleted in this step. When deleting the drawings: ensure that the drawings deleted are duplications not a different drawing with the same name.
10.Start AutoCAD
11.Open the drawing
12.Start AutoPLANT
13.When prompted choose project then choose the original project
14.Once open save the drawing and close
15.Use Relation Ship Manager to move the drawing from your desktop to the previous location
The drawing is now is in the project with a new DOC_ID and it should not display the error when opening.
Thursday, January 14, 2016
AutoCAD Already zoomed out in as far as possible
When I zoom extents I can't do anything my computer seems to freeze. I can zoom previous and regen and it works. There are likely items in "outer space" that may or may not display. If you select all with a crossing you may see some grips that will help find these items.
Use Layman to save the layer state if you want.
Turn on Thaw and unlock all layers.
Zoom extents to see the entire model.
List "All" remove with Crossing the entire model that you can see. Enter
If you "List" "Previous" you should see all the items that you listed.
You will have a list all the objects that are "NOT really there" in the "Previous" que.
Then you can "Erase" "Previous" to get rid if these items.
The items that are left are bad.
You might see some objects that were selected. These items are most likely not needed and are causing the problem. They are not needed because you can't see them anyway! delete the objects by
Use Layman to save the layer state if you want.
Turn on Thaw and unlock all layers.
Zoom extents to see the entire model.
List "All" remove with Crossing the entire model that you can see. Enter
If you "List" "Previous" you should see all the items that you listed.
You will have a list all the objects that are "NOT really there" in the "Previous" que.
Then you can "Erase" "Previous" to get rid if these items.
The items that are left are bad.
You might see some objects that were selected. These items are most likely not needed and are causing the problem. They are not needed because you can't see them anyway! delete the objects by
AutoCAD anonymous blocks *A *X *D *E pugre
1. Dxf out and open the dxf and purge and audit
2. Or turn on unlock thaw all layers, Wblock out "ALL" open new file purg and audit.
*Unnn = anonymous blocks
*E### = anonymous non-uniformly scaled blocks
*X### = anonymous hatches
*D### = anonymous dimensions
*A### = anonymous groups
2. Or turn on unlock thaw all layers, Wblock out "ALL" open new file purg and audit.
*Unnn = anonymous blocks
*E### = anonymous non-uniformly scaled blocks
*X### = anonymous hatches
*D### = anonymous dimensions
*A### = anonymous groups
Wednesday, January 13, 2016
Tuesday, January 12, 2016
AutoCAD (AI) AI_ ERRORS NO FUNCTION DEFINITION
Check the acad2014DOC.lsp is correct and in the correct folder
C:\Program Files\Autodesk\AutoCAD 2014\Support\en-us\acad2014doc.lsp
C:\Program Files\Autodesk\AutoCAD 2014\Support\en-us\acad2014doc.lsp
Subscribe to:
Posts (Atom)